Fetal Monitor 12.1 Inches
Product Description
Description
High-tech fetal monitors, offera reliable, high-performance solution for fetal monitoring needs in doctors’ practices, clinics and hospitals,from pre-natal check-ups to antepartum monitoring of high-risk pregnancies.Apolo B Series is your best partner from antepartum through intrapartum till delivery.
Features
●Newly advanced A8 main board with Linux OS, more stable and safe, the calculating speed is 4 times faster than traditional products
●Foldable 12.1 inches high-brightness LED display, touch screen (optional)
●12-Crystal doppler transducer for accurate detection (waterproof for option)
●Supporting operation with keyboard and mouse (optional)
●Large capacity storage space, 8640 hours memory for fetal traces
●Support medical history search by patient ID, name and mobile number
●FHR signal quality indicator helps optimize the probe position
●On-screen scrolling for viewing stored fetal traces
●Configurable audible and flashing fetal heart rate alarms
●Cross-Channel Verification (CCV) detects coincidence between all fetal and maternal heart/ pulse rates
●Supporting Multi-display mode to meet different clinical requirement, including Fetal-parameter interface, Maternal-parameter interface, Fetal/Maternal-parameter interface, big font, alarm review, ECG review, trend table, trend graph and OxyCRG display
●NIBP self-test mode: including overpressure test, static pressure test and air leakage test.
●Built-in high speed thermal printer, printing width can be selectable to 112mm,150mm
●Internal rechargeable Li-ion battery or AC power from external power supply
●Optional build-in wireless network card, supporting wired or wireless connection to the central monitoring station
●Optional Fischer Non-Stress Test (NST) report software allows interpretation of fetal heart rate and TOCO traces, and generates a printed report automatically for a reassuring NST
●Support HL7 (Health Level Seven, optional)
Specifications
●Ultrasound(FHR)
Transducer type : 12-Crystal ultrasound transducer
Measure method: Wide beam pulse doppler
FHR Measurement range: 30 to 240 bpm (US Standard)
50 to 210 bpm (Europe Standard)
Intensity: <3 mW/cm2
Ultrasound frequency : 1MHz±3%
Resolution: 1 bpm
●TOCO
Measurement method: Strain gauge sensor element
Measure range : 0 ~ 100 units
Resolution: 1 unit
Nonlinear deviation : ≤±8%
Baseline setting : 0,5,10,15, 20 can be selected
Auto offset correction: 3 second after connecting the transducer
Auto zero adjust : TOCO value is set to zero negative
following a negative Measure value for 5 seconds
●Fetal Movement Recording
Automatic fetal movement (AFM): pulsed doppler ultrasound
Automatic fetal movement autograph
Manual fetal movement marker (MFM)
●ECG
Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/Mv, 40mm/Mv,Auto
Accuracy: ±1bpm/ ±1%, whichever is greater
Resolution: 1 bpm
Leakage Current < 10 μA
CMRR: Diagnostic Mode >89 dB
Monitor Mode >105 dB
Surgery Mode >105 dB
Bandwidth
Surgery 1 ~ 25 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 120 Hz
●Heart rate
Measure range: Adult: 0bpm; 10 ~ 300 bpm
Neonate: 0bpm; 10 ~ 350 bpm
Resolution: 1 bpm
Accuracy: ± 1% or ± 1bpm, whichever is greater
●ST measurement
Range: -2.0 ~ +2.0 mV
Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater
Other range: unspecified
Resolution: 0.01mV
●Respiration
Method: Impedance between RA-LL, RA-LA
Gain: ×0.25,×0.50,×1,×2,×4
Respiration Rate: 0bpm; 6 ~ 150 bpm
Resolution: 1 bpm
Accuracy: ±2 bpm or ±2%, whichever is greater
Apnea Alarm: 10 ~ 60s
●SpO2(Digital Technic)
Measurement Range: 0 ~ 100 %
Resolution: 1 %
Accuracy: ±2% (70% ~ 100%)
±3 % (35% ~ 69%)
Unspecified (0 ~ 34%)
●PR
Range: 25~250bpm
Accuracy: ±1% or ±1 bpm, whichever is greater
Resolution: 1bpm
●Maternal NIBP(MNIBP)
Method: Oscillometric
Measure mode Manual, Auto, STAT
Measure Interval in AUTO Mode 1~480 min
STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
Measure and Alarm Range
Systolic: 30~270 mmHg
Diastolic: 10~220 mmHg
Mean: 20~235 mmHg
Static pressure accuracy ±3mmHg
Resolution 1mmHg
Accuracy: Maximum Mean error ±5mmHg
Maximum Standard deviation 8mmHg
Over pressure Protection: Dual protection via software & hardware
●Temperature
Technique : Thermistor probe (2.25K)
Measuring and Alarm Range: 0.0 ℃~ 50 ℃ (32℉~ 122℉)
Unit: Celsius (℃), Fahrenheit ( ℉)
Resolution: 0.1 ℃
Accuracy: ±0.1 ℃
●NST Report (Option)
Based on Fischer Evaluation Method (monitoring time≥20 Min)
Automatic Score Result: Sore:8-10 (Excellent)
Sore:5-7 (Suspicious)
Score:≤4 ( Fetus Hypoxia)
Dimension and Weight
Dimension and Weight
Dimension: 360mm*310mm*120mm
Weight: 5.3kg(excluding accessories)
Power Supply
Voltage:AC100~240V, 50/60HZ
Display
12.1" color LED (0-90° rotation)
Resolution:1024*768 pixels
Battery (Built-in)
Type: Rechargeable lithium battery 14.8V/2200mAh
Charge Cycle: ≥500 times
Working time: 2 hours (optional larger battery for 4-5 hrs)
Recorder (Built-in)
Method: Thermal printer
Paper: Z-fold, thermosensitive
Paper width: 112 mm(4.41 in)/150 mm(5.91 in)
Printing speed: 1/2/3cm/min
Trace: Max. 4 tracks
Recording way: Real-time Recording,
Review Printing
Alarm
Level: Low, medium and high
Indication: Auditory, Visual, Delay of FHR Alarm
Input Device
Touch screen(optional)
Knob (Standard)
Keypad input(Standard)
Mouse/ Keyboard input (optional)
System Output & Extensible Interfac
Ethernet Network: 1 standard RJ45 socket
USB Port : 2
Video Output: 1 HDMI port(optional)
Trend & Reviewing
Cardiotocography (CTG):
Waveform Review: 8640 hours
Vital Signs:
Trend: 2160 hours
Waveform Review: 2 hours
NIBP Review: 2000 groups
Alarm Review: 2000 groups
Safety
IEC60601-1 Approved, CE marking according to MDD93/42/EEC
With reference to RoHS Directive 2011/65/EU recasting
Standard Configuration
●Apolo B1:
Single FHR+ TOCO+ AFM/MFM+ Paper(112 mm)+ Lithium Battery
●Apolo B2:
Single FHR+Dual FHR+ TOCO+ AFM/MFM+Singal Overlap Alarm+ Paper(150 mm)+ Lithium Battery
●Apolo B3:
Single FHR+TOCO+ AFM/MFM+Singal Overlap Alarm+Maternal Parameters (ECG,NIBP,SpO2,PR,RESP,TEMP)+ Paper(112 mm)+ Lithium Battery
●Apolo B4:
Single FHR+Dual FHR+TOCO+ AFM/MFM+Singal Overlap Alarm+Maternal Parameters (ECG,NIBP,SpO2,PR,RESP,TEMP)+ Paper(112 mm)+ Lithium Battery
Optional
●Touch Screen/key Board/Mouse/Central Monitor System
●HDMI/Fetal Simulator/Waterproof Probe/Wall mount/Trolley